GuardShield Safe 2 Operation Manual
Operation Manual GuardShield Safe 2
10. Technical Data
Table 6
Description Value Remarks
Profile length 120 ... 1920 120mm increments
Operating range 0 ... 6 m, Resolution 30 mm
Object detection capability 30 mm
(Resolution)
Power supply U
sp
24 VDC ± 20 % PELV, IEC 60 204-1
Power supply ripple < 10 % of U
sp
Equipment Class III VDE 0106 part 100
Time for self check when switching on U
sp
< 3 s
Current consumption < 500 mA No-load operation
Outputs, short circuit proof 2 x PNP, 0.3 A Max. capacitive load 0.5 µF
Output voltage > U
sp
– 1 Load 0.1 A
Response time t
R-BWS
Selection table
Connector M 12, 5-Pin
Connection cable Max length 5M
Cross section max. 1.5 mm
2
Outside diameter of cable 3 ... 6.5 mm for M12
Mode of operation Guard only with automatic restart
Safety category Type 2 IEC 61496
Standards IEC 61496 part1+2
Electromagnetic compatibility (EMC) IEC 61 496 part 1
Enclosure rating IP65
Temperature range 0 ... +55°C Operation with ILAS
-20 ... +60°C Storage / transport
Relative air humidity 15 ... 95 % Not condensing
Enclosure Aluminum profile 30 x 40 mm
Optical window Polycarbonate, bonded
Enclosure treatment Polyester powder coated
ILAS Laser class 2 EN 60 825
Dimensions Dimensions and selection tables
Weight Selection tables
20 21