GuardShield Safe 2 Operation Manual
Operation Manual GuardShield Safe 2
GuardShield Safe 2 / Safe 4 Narrow Corner Mirror, Catalog Number Wide Corner Mirror, Catalog Number
Protective Height (mm) short range 0...4M Long range 4...15M
120 / 240 440L-AM0750300 440L-AM1250300
360 440L-AM0750450 440L-AM1250450
480 / 600 440L-AM0750600 440L-AM1250600
720 440L-AM0750750 440L-AM1250750
840 440L-AM0750900 440L-AM1250900
960 440L-AM0751050 440L-AM1251050
1080 / 1200 440L-AM0751200 440L-AM1251200
1320 440L-AM0751350 440L-AM1251350
1440 440L-AM0751500 440L-AM1251500
1560 440L-AM0751650 440L-AM1251650
1680 / 1800 440L-AM0751800 440L-AM1251800
1800 None Available None Available
8.3. Accessories / Components
Table 4
ROCKWELL AUTOMATION Description
Part No.
445L-AC5SH-5 5 m PVC shielded cable with M 12 / 5 pin connector, Figure 13
445L-AF6140 Standard mounting kit (4 pieces)
445L-AF6141 Adjustable mounting kit
445L-AF6142 Shock mount kit
445L-AF6144 Mounting kit for POC AND SICK FGS adapter (4 pieces)
445L-AF6150 Optical Interface (incl. software)
Table 5 - Corner Mirror
18
9. Inspection and service
All light curtains contain only electronics and therefore
need limited maintenance.
9.1. Cleaning
The optical windows are to be cleaned with non-
aggressive materials only. The interval between
cleaning is dependant on the air pollution at the
installation.
Do not use aggressive solvents or abrasive
substances. Otherwise range reduction and false
switching could arise.
9.2. Inspections
The light curtain must, depending on the valid
regulations, be periodically tested by qualified and
trained persons.
The function of the light curtain can be tested with the
supplied test rod, which has a diameter corresponding
to the resolution of the light curtain. The status is
indicated through the LED display in the ROCKWELL
AUTOMATION GuardShield Safe 2 light curtain.
Functional Test
The function of the light curtain can be tested using
the test rod, (Figure 12), which has a diameter
corresponding to the resolution of the light curtain.
The status is displayed at the LED on the transmitter
or receiver. The status can be easily read from the
trouble shooting labels “Transmitter Status” and
“Receiver Status” (table 1 and 2, page 13).
9.3. Decommissioning
The safety light curtain may only be removed, if the
machinery or assembly line will be closed definitively.
This has to be done by removing the main supply
from the machinery. It must be impossible to bring the
machinery into operation without using tools.
The light curtain can be reused provided the current
regulations are taken into consideration.
If the light curtain has to be disposed, it can easily
be disassembled and recycled using state of the art
recycling technology and following current disposal
regulation. It does not contain harmful materials
except small quantities of materials used in electronic
PCBs.